CO2 Regulator Bubble Counter Not Working: Setup
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.

If Frigate is frigate not recording any motion suddenly, the most common cause is a recording or retention setting that changed or no longer matches the footage you expect to keep. A zone can stop review items from appearing when it is required, but zones alone do not normally disable the camera’s raw recording stream.
Frigate separates motion detection, object review items, and saved recordings. The live view can look normal even when the recording stream is missing, recording is disabled, or footage is being discarded because no retention rule matches it.
record role for recording.In the Frigate UI, open Settings → Global configuration → Recording. Turn on Enable recording, then check the retention settings. For motion-based retention, set Motion retention → Retention days to a value greater than zero. If you want review clips, also check the alert and detection retention settings and their retention modes.
In YAML, a basic motion-retention setup includes record: enabled: True and motion: days: 3 nested under record. Use the indentation shown in your existing config, then save and apply the configuration. A new motion segment should appear in the timeline after activity; record.enabled: True by itself does not guarantee footage is retained.
Open Settings → Camera configuration → Streams (FFmpeg) and select the affected camera. Confirm that an input is assigned the record role. If you use separate high- and low-resolution streams, verify that the intended high-resolution stream has record and that the detection stream has detect. In YAML, inspect cameras → your_camera → ffmpeg → inputs → roles.
Check the camera’s stream page or logs after applying the change. A functioning live view only proves that a stream works; it does not confirm that Frigate has a recording input.
If the missing items are in Review or Explore, open Settings → Camera configuration → Masks / Zones and inspect the camera’s zones. Check required_zones under the camera’s alert or detection settings. Temporarily clear that requirement or make sure the subject’s path enters the named zone.
This test distinguishes missing object review items from missing video: if review items return but the timeline still has gaps, check recording and retention separately. Zones typically filter review activity; they are not a general switch for saving all motion footage.
Go to Settings → Camera configuration → Motion detection, then open the camera’s debug view and enable motion boxes. Move through the scene or review a time when motion occurred. If boxes do not appear over the subject, inspect Masks / Zones for an oversized motion mask covering that area.
Remove or redraw only the mask that blocks the intended area, then check the debug view again. Visible motion boxes confirm Frigate’s motion detector sees the change; they do not alone confirm that a recording was retained.
Open the camera’s logs from the Frigate system or camera page, depending on your version, and look for repeated FFmpeg restarts or stream connection failures around the missing period. Also verify the RTSP URL and camera credentials if the stream recently changed. Test the same URL with the camera vendor’s app or another RTSP viewer if available.
A stable stream and fresh recording segments confirm the input recovered. If the live feed freezes or the logs show repeated disconnects, restore the camera connection before adjusting motion sensitivity.
Confirm the configured Frigate media directory has free space and is writable by the Frigate container or service. Check the system’s storage view and logs for storage errors. In the Frigate timeline, select a date and time that match the camera’s local activity, remembering that recording timestamps are stored in UTC.
As a quick guide, compare the symptom with the likely cause:
| Cause | Symptom | Quick test |
|---|---|---|
| Retention disabled or zero | Live video works, but old footage is absent | Review Recording retention days |
| Missing record role | Camera detects activity but has no recording segments | Inspect input roles |
| Required zone mismatch | Video exists but expected review items do not | Temporarily clear required zones |
| Motion mask covers subject | No motion boxes appear in that area | Check debug view with motion boxes |
After correcting a setting, allow a new motion event to occur and confirm a fresh segment appears. Past footage that Frigate never saved cannot be recreated from its timeline.
Open Settings → System → Configuration and review the active configuration for validation errors. If you edit YAML directly, check that the changed keys are under the correct camera or global section and that indentation is valid. Apply the config and restart Frigate only if the UI requires it for that change.
A successful apply with no configuration errors, followed by a new saved segment, confirms the fix. If changes appear to have no effect, verify that you edited the configuration file Frigate actually loads.
Motion detection and saved recordings use separate settings. Check that recording is enabled, motion retention is greater than zero, and the camera input has the record role. Review item retention also affects what appears in Review or Explore.
A zone by itself generally does not disable raw recording. A required zone can filter alerts or detections so activity outside that zone does not create the expected review item. Check the recording timeline separately to determine whether video was saved.
Compare the last known good time with recent config edits, updates, camera changes, or storage changes. Then verify recording retention, stream roles, motion boxes, and available storage. This sequence helps identify whether the failure is in detection, review filtering, or recording.
Restore the recording role and a valid retention policy first, then confirm a fresh segment appears after motion. If nothing was saved, check Frigate’s logs and active configuration, and use a camera-side recording or another NVR as a temporary safeguard while you investigate.
Photo: Gzen92 / CC BY-SA 4.0 (Wikimedia Commons)
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.
Fix an aquarium ato float switch stuck by checking buildup, movement, wiring, and controller status, then add safe ATO limits to reduce overflow risk.
Fix reef tank dosing pump calibration with a measured three-point check, tubing inspection, priming, controller steps, and a safe verification run.
Fix apex controller not connecting to wifi by checking AquaBus communication, network compatibility, signal, and Fusion status with practical steps you can try today.
Fix tractive not charging red light issues by checking the charger, contacts, power source, and battery condition, with practical tests to identify the cause.
Fix a tractive tracker not connected to network issue by checking coverage, charging, SIM status, and LTE compatibility before contacting Tractive support.
Fix a petlibro feeder not dispensing by checking food flow, portion settings, the motor, and app connection, with safe steps to confirm the cause.
Fix a Petlibro feeder camera icon that keeps flashing: check Wi-Fi, power, app status, and setup steps to bring the camera back online today.
Petlibro feeder won t connect to wifi? Check your model’s Wi-Fi band, router settings, app permissions, and pairing mode with these practical fixes.
Fix the litter robot 4 pinch detect error by checking the waste drawer, cleaning pinch contacts, reseating the bonnet, and safely testing the cycle.