CO2 Regulator Bubble Counter Not Working: Setup
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.

Hik-Connect shows error code OSCVG4-000013 when you try to open a camera’s live view. The most common cause is that Hik-Connect cannot reach the camera or recorder’s live stream through its current network path, often because the device is offline or its platform connection has dropped.
The message is a live-view connection failure, not a diagnosis of one specific failed component. The app, Hik-Connect service, recorder, camera and local network all have to pass the stream between them.
Use the table to narrow down where the failure occurs before changing settings.
| Possible cause | Typical symptom | Quick test |
|---|---|---|
| Platform connection offline | Remote live view fails for every channel | Check Platform Access status on the recorder |
| Camera or channel issue | Only one camera fails | Open that channel on the recorder’s local monitor |
| Network restriction | Live view works on Wi-Fi but not mobile data | Try another internet connection with VPN disabled |
Try several channels in Hik-Connect, then check the same cameras on the NVR’s local monitor or web interface. If only one channel fails, inspect that camera’s power, Ethernet link and channel status in the recorder’s camera list. If every channel fails remotely, focus on the NVR’s network and Hik-Connect connection. A working local view confirms the camera is producing video, but does not prove remote access is configured correctly.
On the recorder, open Configuration > Network > Advanced Settings > Platform Access; menu wording and location can vary, so check your model’s menu. Confirm Hik-Connect is enabled and the status reads Online. If it is offline, check the recorder’s gateway and DNS settings, then restore internet access and refresh the status. An online status is the result you want before testing live view again.
In the recorder’s network settings, confirm the IP address, subnet mask, default gateway and DNS values are valid for your network. The gateway should lead to your router; a static address outside the router’s subnet can leave local cameras visible while internet access fails. If the recorder uses DHCP, check that it receives a lease and gateway. Save only settings you understand, then confirm Platform Access returns to Online.
On the local monitor, open each affected channel. In the camera or channel management screen, look for an online status and any authentication or connection warning. For a directly connected IP camera, confirm it has power and a network link; for a camera connected through an NVR, check the NVR’s camera list. If local video is absent, fix that camera connection first; the app cannot display a stream the recorder itself cannot receive.
In Hik-Connect, switch the live-view stream between HD and Fluent or the equivalent options shown by your app version. A lower-bandwidth stream may load when the main stream times out on a slow uplink. If neither works, inspect the camera’s encoding settings on the recorder and check that the selected stream is enabled. A successful Fluent view points to bandwidth or stream-load limits; it does not by itself identify which one.
Confirm the device appears in the Hik-Connect account currently signed into the app. If it was shared by another user, ask the owner to verify the sharing permission includes live view and the affected channels. If the device was recently moved to another account, remove stale app entries only after confirming the correct account owns or shares it. Seeing the device and its channels under the active account confirms the app has a valid device association.
Test live view on the recorder’s local Wi-Fi, then turn Wi-Fi off and test over mobile data. Temporarily disconnect a phone VPN or private relay if one is active. If one network works and the other does not, check that network’s firewall, DNS filtering or router restrictions; avoid opening ports broadly as a first fix. Success on both networks suggests the connection path is available from each.
Update Hik-Connect through your device’s official app store, close and reopen it, and sign out and back in if the device listing or stream appears stale. Restart the recorder only when recording can safely pause, and allow it to reconnect before testing. If you still see hikvision error code oscvg4 000013, note the model, firmware, app version, Platform Access status and whether local live view works; these details help Hikvision support isolate the issue without guessing.
It appears when Hik-Connect cannot open the requested live view. The message alone does not identify whether the cause is the network, recorder, camera channel or account access.
The mobile network may use a different route or apply restrictions that prevent the stream from connecting. Disable any phone VPN for a test, then compare with another mobile connection; if only one network fails, investigate that network’s filtering or DNS.
Yes. Local video confirms the camera can reach the recorder, but remote viewing also depends on the recorder’s internet connection, Platform Access status and app permissions. Check those items before changing camera encoding or resetting equipment.
Start with local channel status and Platform Access, then test stream quality and network differences to narrow down the failure. If none of these fixes restores live view, contact Hikvision support or your installer with the model, firmware, app version and test results.
Photo: Gzen92 / CC BY-SA 4.0 (Wikimedia Commons)
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.
Fix an aquarium ato float switch stuck by checking buildup, movement, wiring, and controller status, then add safe ATO limits to reduce overflow risk.
Fix reef tank dosing pump calibration with a measured three-point check, tubing inspection, priming, controller steps, and a safe verification run.
Fix apex controller not connecting to wifi by checking AquaBus communication, network compatibility, signal, and Fusion status with practical steps you can try today.
Fix tractive not charging red light issues by checking the charger, contacts, power source, and battery condition, with practical tests to identify the cause.
Fix a tractive tracker not connected to network issue by checking coverage, charging, SIM status, and LTE compatibility before contacting Tractive support.
Fix a petlibro feeder not dispensing by checking food flow, portion settings, the motor, and app connection, with safe steps to confirm the cause.
Fix a Petlibro feeder camera icon that keeps flashing: check Wi-Fi, power, app status, and setup steps to bring the camera back online today.
Petlibro feeder won t connect to wifi? Check your model’s Wi-Fi band, router settings, app permissions, and pairing mode with these practical fixes.
Fix the litter robot 4 pinch detect error by checking the waste drawer, cleaning pinch contacts, reseating the bonnet, and safely testing the cycle.