If your ICOM IC-7300 will not communicate with WSJT-X, the software may show no frequency, fail to control the radio, or leave transmit and receive unchanged. The most common cause is selecting the wrong USB serial COM port, often because Windows exposes separate ports for radio control and audio.
The IC-7300 connects to a computer over USB, but WSJT-X needs the radio’s CAT control connection to be configured separately from its audio input and output. A working USB audio device does not prove that CAT control is working.
Disconnect the radio’s USB cable, install the current IC-7300 USB driver from Icom’s support materials for your operating system, then reconnect the radio and turn it on. In Windows, open Device Manager and expand Ports (COM & LPT). Note the COM port associated with the Icom USB-to-serial device; if two Icom ports appear, don’t assume the first one is the CAT port. Check the driver documentation and test the candidates in WSJT-X. The confirming result is a stable port entry that disappears when you unplug the radio and returns when you reconnect it.
In WSJT-X, open File > Settings > Radio. Choose ICOM IC-7300 if it appears in the radio list; otherwise use the Icom option supported by your version and enter the radio’s CI-V address as specified in the IC-7300 manual. Select the COM port identified in Device Manager, then set PTT Method to CAT and Mode to Data/Pkt or the equivalent option available in your version. Click Test CAT. A successful test and a frequency readout in WSJT-X confirm that CAT control is working.
On the IC-7300, open the menu’s Set area and look under Connectors for the CI-V options. Menu wording can vary by firmware, so check your model’s manual if the labels differ. Compare the radio’s CI-V address and baud rate with the settings in WSJT-X. For the first test, use a fixed baud rate supported at both ends instead of an automatic setting if available. Don’t change CI-V transceive or USB serial settings at random; adjust only a mismatch. Retest CAT after each change. A correct match should let WSJT-X read the frequency reliably.
Close other radio-control and logging programs, including rig-control utilities, another WSJT-X instance, and any application that may be polling the IC-7300. Only one program can usually control a serial port at a time. Reopen WSJT-X and click Test CAT. If it works only after another program closes, the cause was a port conflict; keep that application closed or configure a rig-control server if you need multiple clients.
Review the IC-7300’s USB serial and CI-V options in Set > Connectors (confirm the exact labels in your manual). Ensure USB serial control is enabled and the control mode is appropriate for direct computer CAT access. The USB audio codec can remain available independently. After changing a control setting, disconnect and reconnect USB, then restart WSJT-X so it redetects the interface. The test passes when the COM port remains present and WSJT-X can read frequency.
Open File > Settings > Audio in WSJT-X and select the IC-7300 USB audio device for input and output. On Windows, these may appear as separate playback and recording devices with Icom or USB audio in their names. Use the WSJT-X input level meter or waterfall to confirm received audio, and verify transmit audio with a brief, safe test according to your operating practice. If the waterfall works but Test CAT fails, audio is fine and the remaining issue is serial control configuration.
| Cause | Symptom | Quick test |
|---|---|---|
| Wrong COM port | CAT test fails, but USB audio works | Try the Icom port that tracks USB unplugging |
| Port conflict | CAT works only intermittently or after closing an app | Close other radio-control software and retry |
| CI-V mismatch | Port opens but frequency does not update | Compare radio address and baud rate with WSJT-X |
Change one setting at a time and repeat Test CAT; that makes the result useful instead of introducing several new variables.
Frequency readout confirms that at least part of CAT communication works, but PTT may be configured differently. Check File > Settings > Radio > PTT Method and select CAT if that is your intended control method. Confirm the radio is not in a transmit-inhibited state and follow safe on-air testing practice.
Choose the serial port tied to the radio’s CAT control, not the USB audio device. Device Manager can show which entries appear and disappear with the radio; if multiple Icom ports are listed, use the driver documentation and test each plausible port with Test CAT.
USB audio and CAT control are separate functions, so receive audio can reach WSJT-X even when its serial settings are wrong. Check the COM port, CI-V address and baud rate, and whether another program has opened the port.
If the IC-7300 still will not communicate with WSJT-X, record the selected COM port, radio CI-V settings, operating system, and WSJT-X version, then compare them with the current Icom manual and WSJT-X documentation. If the port never appears or fails outside WSJT-X too, reinstall the Icom driver and test another USB cable or computer before changing more radio settings.
Photo: Jebulon / CC0 (Wikimedia Commons)
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.
Fix an aquarium ato float switch stuck by checking buildup, movement, wiring, and controller status, then add safe ATO limits to reduce overflow risk.
Fix reef tank dosing pump calibration with a measured three-point check, tubing inspection, priming, controller steps, and a safe verification run.
Fix apex controller not connecting to wifi by checking AquaBus communication, network compatibility, signal, and Fusion status with practical steps you can try today.
Fix tractive not charging red light issues by checking the charger, contacts, power source, and battery condition, with practical tests to identify the cause.
Fix a tractive tracker not connected to network issue by checking coverage, charging, SIM status, and LTE compatibility before contacting Tractive support.
Fix a petlibro feeder not dispensing by checking food flow, portion settings, the motor, and app connection, with safe steps to confirm the cause.
Fix a Petlibro feeder camera icon that keeps flashing: check Wi-Fi, power, app status, and setup steps to bring the camera back online today.
Petlibro feeder won t connect to wifi? Check your model’s Wi-Fi band, router settings, app permissions, and pairing mode with these practical fixes.
Fix the litter robot 4 pinch detect error by checking the waste drawer, cleaning pinch contacts, reseating the bonnet, and safely testing the cycle.