CO2 Regulator Bubble Counter Not Working: Setup
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.

Victron Error 67 “No BMS” means a managed battery is not providing the battery-management data the system expects. The most common cause is a CAN connection or battery communication profile that is wrong, loose, or connected to the wrong port—not a failed inverter.
With a supported managed battery, the BMS sends data such as charge limits, discharge limits, and state of charge to a Victron GX device over a supported communication link. If that data is missing or incompatible, the GX device cannot manage charging as configured.
Check the battery maker’s compatibility documentation for your exact battery model and firmware, then compare it with Victron’s compatibility information for managed batteries. A battery that merely has a CAN port is not automatically compatible: EcoFlow, Bluetti, and Anker SOLIX products, for example, do not all expose a Victron-compatible BMS link. If the battery is not supported for your system, Error 67 may be expected; use a supported integration or the battery maker’s approved operating setup instead of trying random profiles.
Turn off charging sources and follow the equipment makers’ shutdown instructions before reseating cables. Verify that the battery communication cable runs from the battery’s designated CAN port to the correct GX CAN port, not an Ethernet or VE.Can port chosen by appearance alone. Check the battery manual for cable pinout and termination requirements; ordinary Ethernet patch cables are not interchangeable with every CAN cable. A secure, correctly terminated link is the result to look for.
On the GX device, open Settings > Services > VE.Can port (wording may vary by GX model and software version) and check the CAN-bus profile. Select the profile specified for your battery integration, such as the documented CAN-bus BMS profile when that is what the battery maker requires. Do not select a profile based only on the connector type. After applying the setting, check the device list or battery page for a recognized BMS and live battery data.
Use the battery maker’s app, display, or setup instructions to enable its Victron or CAN communication mode if one is required. Confirm that the battery is awake, has no active internal BMS shutdown, and is set to the correct system role or master-battery arrangement for a parallel bank. The confirming result is that the battery reports normal operating status and the GX device begins receiving data; consult the battery manual for model-specific indicators.
On current GX versions, open Settings > System setup > DVCC and review the available options and status. DVCC behavior and menu labels vary by system, so check your model’s menu and the battery integration instructions before changing controls such as shared voltage sense or charge-current limits. When communication is healthy, the GX device should show BMS-provided charge and discharge limits where supported. Do not override limits to hide a communication fault.
Once wiring and settings are checked, restart the battery and GX device using the manufacturers’ procedures. If the battery bank has a master unit, bring it online according to its manual before bringing up the GX device; then allow the system time to rediscover devices. Look for the BMS in the device list and confirm that its values update. Avoid repeatedly power-cycling an energized battery system or disconnecting CAN while equipment is operating.
| Likely cause | Typical symptom | Quick test |
|---|---|---|
| Unsupported battery link | No BMS appears despite a CAN socket | Check the exact model in compatibility documentation |
| Wrong port or cable | Communication stays absent after restart | Verify port labels, pinout, and termination in both manuals |
| Wrong GX profile | Battery is powered but not recognized | Compare VE.Can profile with the battery integration guide |
| Battery asleep or faulted | Link appears intermittent or battery data is unavailable | Check battery status in its own app or display |
It indicates that the system is not receiving the expected BMS communication for a managed battery. The cause may be compatibility, cabling, port selection, configuration, or a battery that is not online.
Changing DVCC alone does not restore missing battery communication. First confirm the battery link and the correct GX CAN profile, then review DVCC options against the battery integration instructions.
A CAN connector only identifies a communication interface; it does not guarantee a compatible protocol or cable pinout. Check the exact battery model’s Victron support, required cable, and GX profile.
Victron Error 67 “No BMS” is usually resolved by confirming compatibility, correcting the CAN link, and matching the GX profile to the battery instructions. If the warning remains, record the battery model and firmware, GX model and software, selected CAN profile, and device status, then contact Victron or the battery maker with those details.
Photo: FarmBot / CC BY 4.0 (Wikimedia Commons)
Fix an aquarium co2 regulator bubble counter that stays still, empties, or bubbles unevenly. Check assembly, leaks, pressure, tubing, and safe CO2 flow.
Fix an aquarium ato float switch stuck by checking buildup, movement, wiring, and controller status, then add safe ATO limits to reduce overflow risk.
Fix reef tank dosing pump calibration with a measured three-point check, tubing inspection, priming, controller steps, and a safe verification run.
Fix apex controller not connecting to wifi by checking AquaBus communication, network compatibility, signal, and Fusion status with practical steps you can try today.
Fix tractive not charging red light issues by checking the charger, contacts, power source, and battery condition, with practical tests to identify the cause.
Fix a tractive tracker not connected to network issue by checking coverage, charging, SIM status, and LTE compatibility before contacting Tractive support.
Fix a petlibro feeder not dispensing by checking food flow, portion settings, the motor, and app connection, with safe steps to confirm the cause.
Fix a Petlibro feeder camera icon that keeps flashing: check Wi-Fi, power, app status, and setup steps to bring the camera back online today.
Petlibro feeder won t connect to wifi? Check your model’s Wi-Fi band, router settings, app permissions, and pairing mode with these practical fixes.
Fix the litter robot 4 pinch detect error by checking the waste drawer, cleaning pinch contacts, reseating the bonnet, and safely testing the cycle.